Crude Palm Oil, Centrifugal Pump, ViscosityAbstract
This test is to see the performance of the pump in series and parallel installation using a centrifugal
booster pump to drain Crude Palm Oil. The fluid flow is monitored by a pressure gauge as a pressure detector
and a flowmeter as a flow meter to detect Crude Palm Oil’s flow. Has a reservoir with a volume of 45 liters, and
uses a 1 inch galvanized pipe. The largest pressure value is obtained by a series pump circuit, of 6 Psi. While the
lowest pressure value is obtained by a parallel pump circuit, which is 3 Psi. At a temperature of 80°C, the largest
flow rate produced by a parallel circuit is 60 lpm, while the smallest discharge is produced by a series pump
circuit of 32 lpm. Meanwhile, at room temperature, the parallel circuit flow rate was recorded at 17 lpm, and the
series pump circuit as much as 12 lpm. The pump with the best efficiency with a series circuit is 97%, while in a
parallel pump circuit it is 89%.